Specifying fire glazing: internal, external and sealed units

Once the fire strategy has set the rating, the next decisions are practical ones. Interior laminate or an exterior sealed unit? How thick and how heavy? What happens to the U-value? This guide works through them with Jaden EI glass, and ends with what to put on an enquiry.

Two builds

Interior laminate or exterior sealed unit

The fire resisting part is the same in both. What changes is what surrounds it.

Jaden EI-IN

Interior EI Glass

Two faces of 5 or 6mm glass, with an intumescent liquid gel between.

For screens, partitions, doors, stair enclosures and atriums inside the building. Very clear, at 86% to 87% light transmission, with strong sound reduction. As a single laminate its U-value is 5.6 W/m²K, so it is not meant for the outside of a heated building.

Jaden EI-EX ISO

Exterior EI Glass

Two faces of 5 or 6mm glass, with an intumescent liquid gel between, plus an additional 12mm spacer bar, with a 6mm Low E or solar control outer.

For external walls, curtain walling and shopfronts. The sealed cavity and coated outer pane bring the U-value down to 1.4 W/m²K, and the outer pane can be chosen for solar control. Light transmission is 74% or so.

Side by side

Internal and external compared, rating by rating

Each cell gives the interior figure first, then the exterior unit. Sound reduction is the same for both.
Jaden EI glass, interior and exterior, by fire rating
Rating Thickness (in / ex) Weight kg/m² (in / ex) Light (in / ex) U-value W/m²K (in / ex) Sound Rw dB
EI-30 22 mm / 38 mm 40 / 50 87% / 74% 5.6 / 1.4 43
EI-60 28 mm / 44 mm 46 / 56 86% / 73% 5.6 / 1.4 44
EI-90 34 mm / 50 mm 53 / 63 86% / 73% 5.6 / 1.4 46
EI-120 50 mm / 66 mm 71 / 81 86% / 73% 5.6 / 1.4 46

Weight sets the frame

Even the lightest build, interior EI 30, weighs 40 kg/m², and an exterior EI 120 unit weighs 81 kg/m². A pane 1 m by 2 m at EI 60 weighs about 92 kg before it is framed. The framing system, setting blocks and fixings must be rated for it, and lifting it into place needs planning.

Thickness sets the glazing details

The jump from EI 30 to EI 120 more than doubles the thickness, from 22 mm to 50 mm inside and from 38 mm to 66 mm outside. The frame's glazing rebate and beads have to suit the build, so settle the rating before the framing is chosen.

Practicalities

Four things that catch people out

It is made to size
EI glass cannot be cut on site. Each pane is made to the finished size ordered, so measure from the frame it will go into, not from drawings that may change.
The edges matter
The edge seal keeps the gel in and the fire performance intact. A chipped or crushed edge can mean a rejected pane, so protect edges during storage, handling and glazing.
Interior grade stays inside
Interior grade glass should be shaded but ventilated in transport and on site, and kept out of rain and extreme weather. If it will face strong sunlight in service, tell us at the enquiry stage.
Lift a sealed unit by its fire glass
On an exterior unit, the weight must never be taken on the outer solar control pane. Support the base with slings, and use suckers on the fire glass side only.

Our delivery and handling page has the full handling directions for EI glass.

Enquiries

What to send us for a quotation

The more of this we have at the start, the quicker and more accurate the price.
  1. The rating

    The class and minutes for each pane, from the fire strategy: EI 30, EI 60, EI 90 or EI 120.

  2. Inside or outside

    Interior laminate, or an exterior insulating unit with low E or solar control glass on the outside.

  3. Finished sizes

    Width and height of each pane, measured for the frame it is going into, and how many of each.

  4. The framing system

    The fire rated system the glass will be installed in, so the sizes and classification match.

  5. Where it is going

    Anything unusual about the location, such as strong sunlight, an unheated space or high level installation.

  6. Delivery

    The site address, access for a crated delivery, and how the glass will be offloaded.

Not sure which rating applies where? Our guides to E, EW and EI ratings and where EI glass is required cover the background.

Common questions

Specifying fire glass, answered

Can EI fire glass be cut on site?
No. EI glass with a gel interlayer is made to size, and cutting it would destroy the edge seal and the fire performance. Order to finished sizes, measured for the frame it will go into.
What is the difference between Jaden EI-IN and EI-EX ISO?
EI-IN is the interior laminate: two faces of 5 or 6 mm glass with an intumescent gel between. EI-EX ISO adds a 12 mm spacer and a 6 mm low E or solar control outer pane, making an insulating unit for external walls with a much lower U-value.
Can interior EI glass be used in an external wall?
It is not designed for it. Interior grade glass should be kept shaded, and on its own it has a single glazing U-value. For external walls and curtain walling, specify the exterior insulating unit.
How heavy is EI fire glass?
Heavy. Jaden interior EI glass weighs from 40 kg/m² at EI 30 to 71 kg/m² at EI 120, and the exterior units from 50 to 81 kg/m². Framing, setting blocks, handling and offloading all have to allow for it.
Is EI glass safety glass?
Jaden EI glass is classified for safety under EN 12600 as well as for fire resistance, so it can be used where the regulations call for safety glazing, such as doors and low level screens.
Does EI glass reduce noise?
Yes. Its layered build gives a sound reduction of 43 to 46 dB (Rw), depending on the rating, which makes it a good choice for office partitions and meeting rooms.

Sources

  • Jaden Glass Ltd product data for interior and exterior EI glass: light transmission to EN 410, sound reduction and U-value to EN 673, safety to EN 12600. See the fire resistant glass page.
  • Jaden Glass Ltd technical delivery conditions and EI glass handling directions. See delivery and handling.
  • BS EN 13501-2, Fire classification of construction products and building elements. British Standards Institution.

Last reviewed 3 November 2026. This guide is general information. Final specifications should follow the fire strategy for the building and the classification report for the glazing system used.

Ready to price a fire glazing package?

Email info@jadenglass.com or call +44 (0)777 962 8185.

Send an enquiry